VW3-63 series smart air circuit breaker, ACB
- Tailored for photovoltaic, wind power and energy storage systems
- High-voltage air circuit breaker, optional 800Vac, 1140Vac, 1250Vac, 1500Vac
- With ultra-high breaking capacity, max meet 85kA at 800Vac
- With excellent anti damp heat and dew solidification capabilities
- Strong ability to adapt to alternating changes in high and low temperatures
- Strong resistance to salt spray and humid environments
Technical parameters
Rated current In(A) | 4000A, 5000A, 6300A |
Rated working voltage Ue(V) 50Hz/60Hz | AC400, AC690, AC800, AC1140, AC1500 |
Rated insulation voltage Ui(V) | 1800V |
Rated impulse withstand voltage Uimp(kV) | 18kV |
Power frequency withstand voltage U(V) 1min | AC5000V 50Hz/60Hz |
Number of poles | 3P, 4P |
N-pole rated current | 50%In |
Breaking capacity code | H, HU, HV |
Rated limit short-circuit breaking capacity (effective value) Icu(kA) |
AC400: 135kA AC690: 120kA AC800/AC1140: 85kA AC1500: 50kA |
Rated operating short-circuit breaking capacity (effective value) Ics(kA) |
AC400: 135kA AC690: 120kA AC800/AC1140: 85kA AC1500: 50kA |
Rated short circuit making capacity (peak value) Icm(kA) |
AC400: 297kA AC690: 264kA AC800/AC1140: 187kA AC1500: 105kA |
Rated short-time withstand current (effective value) Icw(kA) 1s |
AC400: 135kA AC690: 120kA AC800/AC1140: 85kA AC1500: 50kA |
Rated conditional short-circuit current Icc(kA) | AC400: 135kA AC690: 120kA AC800/AC1140: 85kA AC1500: 50kA |
Full break time (no additional delay) (ms) | 12(ms)~18(ms) |
Closing time (ms) | ≤60(ms) |
Operating performance(Mechanical life (times); Without maintenance) | 6500(times) |
Operating performance(Mechanical life (times); Maintenance) | 13000(times) |
Operational condition(Utilization category) | B |
Operational condition(Pollution degree) | 3 |
Operational condition(Ambient grade) | IP40 |
Operational condition(Ambient temperature) | ≥-40℃ |
Operational condition(Altitude) | ≤5000m |
Outline dimension (mm) (H × W × D) (Drawout type 3P) | 480(mm) × 853(mm) × 395(mm) |
Outline dimension (mm) (H × W × D) (Drawout type 4P) | 480(mm) × 900(mm) × 395(mm) |
Outline dimension (mm) (H × W × D) (Fixed type 3P) | 390(mm) × 800(mm) × 297.5(mm) |
Outline dimension (mm) (H × W × D) (Fixed type 4P) | 390(mm) × 915(mm) × 297.5(mm) |
Tips: For more information, please refer to the user manual or specification sheet in the following documentation.
Highlights
Related Products
VW3-25 ACB crafted for PV, wind, & storage systems. Features 3P/4P and Icu:50kA~85kA. Peak breaking...
VW3-40 ACB engineered for PV, wind, & storage. Boasts 3P/4P & Icu:50kA~100kA. Breaks up to...
VW3-63 ACB, the choice for PV, wind, & storage. Equipped with 3P/4P & stellar Icu:50kA~135kA....
Intelligent manufacturing